Search results for "Lumen Diameter"
showing 4 items of 4 documents
A novel 3-d reconstruction system for the assessment of bifurcation lesions treated by the mini-crush technique.
2010
Background: Conventional two-dimensional angiography lacks the ability to properly image the true bifurcation geometry, and its percutaneous coronary intervention-induced changes in the clinical setting. Methods and Results: A novel three-dimensional reconstruction system was investigated by retrospectively analyzing 39 lesions in 35 consecutive patients with coronary bifurcation disease treated with the mini-crush technique. At baseline, significant correlations were proved between two- and three-dimensional systems in terms of either reference vessel diameter (R 2 = 0.68 and 0.29 for main and side branches, respectively), minimum lumen diameter (R 2 = 0.73 and 0.36), stenosis diameter (R …
Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents
2020
Recently, multilayer stents for type B aortic dissections (TBAD) have been proposed to decrease false lumen flow, increase and streamline true lumen flow, and retain branch vessel patency. We aimed to provide a protocol with standardized techniques to investigate aortic remodeling of TBAD by multilayer flow modulators (MFM) in static geometric and hemodynamic analyses. Combining existing literature and new insights, a standardized protocol was designed. Using pre- and postoperative CT scans, geometric models were constructed, lumen dimensions were calculated, computational fluid dynamics (CFD) models were composed, and velocity and pressures were calculated. Sixteen TBAD cases treated with …
The ultra-thin bronchoscope in management of the difficult paediatric airway
1987
The use of an ultra-thin flexible fiberoptic bronchoscope with a single lumen diameter of 2.7 mm at the distal tip to assist intubation of paediatric patients with a difficult airway is reported. Two patients (ages 30 months and 18 months) with mandibular hypoplasia and one patient (three months) with the Pierre-Robin syndrome are reported. In each case two fiberoptic bronchoscopes were used. The first allowed introduction of topical local anaesthetic while the second and smaller one was used for tube placement.
Early and midterm outcomes of bioresorbable vascular scaffolds for ostial coronary lesions: insights from the GHOST-EU registry.
2016
Aims: We aimed to investigate the outcomes of bioresorbable vascular scaffolds (BVS) in coronary ostial lesions. Ostial lesions represent a challenging angiographic subset, with higher event rates compared with non-ostial lesions. BVS might be associated with advantages over the long term, but their safety in this setting remains to be explored. Methods and results: Procedural and 12-month follow-up data from consecutive patients treated with BVS for lesions located at the ostium of the right (RCA), left anterior (LAD) or circumflex (LCX) coronary in 11 European centres were collected. The primary device-oriented endpoint was defined as a combination of cardiovascular death, target vessel m…